Appendix: WDR Mighty Dome
6) ZONE ADJ. Menu
Adjusts the size and the location of the metering zone for the dynamic range control.
Dynamic range control is very sensitive to the size and the location of the zone.
The default window size is SAFE AREA.
To enter ZONE ADJ menu, press button at <ZONE ADJ . . .> of WDR CUSTOM menu.
In ZONE ADJ menu, 'NEXT:MENU-' stands for 'press button short for next menu'
and 'RETURN:MENU---' means 'press button longer than 2 sec for return or exit'.
, , , buttons are used for move, enlarge or reduce the zone.
White zone boundary moves the zone to locate it at the optimal position.
Green zone boundary enlarges the zone.
Red zone boundary reduces the zone.
7) BLC ZONE SELECT menu
To enter BLC ZONE SELECT menu, press button at <BLC . . . > of EXPOSURE menu.
Metering of the back lit compensation control is weighted to the selected window from CTR
SPOT(1/9 of
entire screen), UPPER 1/3, MIDDLE 1/3 and LOWER 1/3.